Pressure Transducer Mechanical Drawing
|  
 Pressure Transducer Specifications Part Number  | 
  
 Range  | 
  
 Accuracy  | 
  
 Type  | 
| 
 PT-0-3PSI-01  | 
 0 to 3 PSI (0.21 bar)  | 
 ± 2% Full Scale  | 
 Gauge  | 
| 
 PT-0-5PSI-01  | 
 0 to 5 PSI (0.34 bar)  | 
 ± 2% Full Scale  | 
 Gauge  | 
| 
 PT-0-10PSI-01  | 
 0 to 10 PSI (0.69 bar)  | 
 ± 2% Full Scale  | 
 Gauge  | 
| 
 PT-0-50PSI-01  | 
 0 to 50 PSI (3.45 bar)  | 
 ± 1% Full Scale  | 
 Gauge  | 
| 
 PT-0-100PSI-01  | 
 0 to 100 PSI (6.89 bar)  | 
 ± 0.5% Full Scale  | 
 Gauge  | 
| 
 PT-0-500PSI-01  | 
 0 to 500 PSI (34.47 bar)  | 
 ± 0.5% Full Scale  | 
 Absolute  | 
| 
 PT-0-3000PSI-01  | 
 0 to 3000 PSI (206.84 bar)  | 
 ± 0.5% Full Scale  | 
 Absolute  | 
|   
 Specification  | 
  
 Value  | 
| 
 Operating Temperature  | 
 -40°C to 105°C  | 
| 
 Storage Temperature  | 
 -40°C to 105°C  | 
| 
 Proof Pressure  | 
 2.4 Full Scale  | 
| 
 Burst Pressure  | 
 2.4 Full Scale  | 
| 
 Reverse Voltage Protection  | 
 ± 16V over 5 Minutes  | 
| 
 Construction  | 
 304L stainless steel  | 
| 
 Pressure/Temperature Cycles  | 
 0 to FS @ 8Hz; and ?40°C to 105°C for > 1.8×106 cycles  | 
| 
 Thermal Shock  | 
 105°C to ?40°C, 0.5 hr soaks at Temp. (2s Transfer) for 300 cycles  | 
| 
 Vibration  | 
 100 to 2000 Hz, 20g Sinusoidal, 3 Axes for 144 hours  | 
| 
 EMC Compatibility  | 
 10 Volts/meter per EN 61000-4-3  | 
| 
 Humidity  | 
 85°C and 90% to 95% R. H. for 250 hours  | 
| 
 Weight  | 
 85g  | 
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov.