Raymarine Evolution ACU Specifications
| Model | ACU-100 | ACU-200 | ACU-300 | ACU-400 | 
| E70098 | E70099 | E70139 | E70100 | |
| 
 
  | 
||||
| Drive Current Output |  Maximum continuous 
 7 A at supply voltage  | 
Maximum continuous 15 A at supply voltage |  Maximum continuous 5 A 
 at supply voltage  | 
Maximum continuous 
 30 A at supply voltage  | 
| Drive Clutch Output | No clutch connection | Up to 2.0 A continuous, selectable between 12 /24 V | No clutch connection | 
  | 
| Connections | 
 
  | 
 
  | 
 
  | 
  | 
| Nominal supply voltage | 
 12 V  | 
 12 V or 24 V  | 
||
| Operating voltage range | 
 10.8 V to 15.6 V dc  | 
 10.8 V to 31.2 V dc  | 
||
| Power consumption (standby) – main power supply | 
 300 mA (12V)  | 
 300 mA (12/24 V)  | 
||
| Power consumption (standby) – SeaTalkng power supply | 
 No power supply to SeaTalkng&nbs p;  | 
 20 mA (12V)  | 
||
|  SeaTalkng LEN 
 (Load Equivalency Number)  | 
 1  | 
|||
| SeaTalkng Power out | 
 No power supply to SeaTalkng  | 
 3 A at 12 V (fuse protected at 3 A)  | 
||
| Data connections | 
 SeaTalkng  | 
|||
| Installation environment | 
 Operating temperature: -20°C to +55°C (-4°F to +131°F) Storage temperature: -30°C to +70°C (-22°F to +158°F) Relative humidity: max 93%  | 
|||
| Waterproof rating | 
 Connector panel: IPX2 Drive electronics: IPX6  | 
 Drip resistant  | 
||
|  Dimensions 
 (W x H x D)  | 
 180 mm x 140 mm x 52 mm (7.1 in x 5.5 in x 2.0 in)  | 
 285 mm x 211.5 mm x 64.5 mm (11.2 in x 8.3 in x 2.5 in)  | 
||
| Weight | 
 0.6 kg (1.32 lbs)  | 
 2.2kg (4.84 lbs)  | 
||
| Conformance | 
 Europe: 2004/108/EC Australia and New Zealand: C-Tick, Compliance Level 2  | 
|||
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov.